Measuring range
35 m
Process temperature
-196 ... 450 °C
Process pressure
-1 ... 160 bar
Accuracy
± 2 mm
Frequency
26 GHz
Beam angle
≥ 3°
Version
for separate horn antenna with ½" standpipe with horn antenna ø 40 mm with horn antenna ø 48 mm with horn antenna ø 75 mm with horn antenna ø 95 mm with parabolic antenna ø 245 mm
Materials, wetted parts
316L Alloy C22 (2.4602) 1.4848 Alloy 400 (2.4360)
Threaded connection
G1½, 1½ NPT
Flange connection
≥ DN50, ≥ 2"
Seal material
FKM FFKM graphit and ceramic
Housing material
Plastic Aluminium Stainless steel (precision casting) Stainless steel (electropolished)
Protection rating
IP66/IP68 (0,2 bar) IP66/IP67 IP66/IP68 (1 bar)
Output
Profibus PA Foundation Fieldbus 4 … 20 mA/HART - two-wire Modbus 4 … 20 mA/HART - four-wire
Ambient temperature
-40 ... 80 °C
Approvals
Scope ATEX / Europe CSA / Canada FM / USA EAC (GOST) / Belarus EAC (GOST) / Kazakhstan EAC (GOST) / Russia IEC / worldwide KOSHA / Korea NEPSI / China UKR Sepro / Ukraine IEC / Australia
Explosion protection
Intrinsic safety "i" Flameproof enclosure "d" Dust explosion protection through housing "t"
Ship approval
ABS BV CCS DNV GL KR LR NK RINA RMROS
Overfill protection
WHG
SIL qualification
SIL2
Display & adjustment
Adjustment PLICSCOM PC, PACTware and DTM HART-Communicator Software (e. g. AMS™, PDM) Indication Display/adjustment module PLICSCOM VEGADIS 81 VEGADIS 82